== [[Image:Sketch.png]] [[Slicer3:UIDesign:WorkingProblems:Slicer_Load_Using_XNAT_Tools | Link to info for A. Slicer Consolidated Load and XNAT Desktop/File Server integration]] == | == [[Image:Sketch.png]] [[Slicer3:UIDesign:WorkingProblems:Slicer_Load_Using_XNAT_Tools | Link to info for A. Slicer Consolidated Load and XNAT Desktop/File Server integration]] == |
Revision as of 13:24, 2 December 2009
Home < Slicer3:UIDesignReturn to Slicer3 Interface Design and Usability
Contents
- 1 Slicer users
- 2 User Feedback: Feature, Resource, Application Convention Requests
- 3 Some Embodiment History
- 4 Codes to mark contributions
- 5 Working problem: Consolidated Load in Slicer including an extended XNAT Desktop and File Server
- 6 Working problem: CTSC: Facilitating Tumor Analysis Workflow in Slicer
- 7 Working problem: Customizable layouts for Slicer3
- 8 Working problem: Slicer3 workflow for Tractography: usability issues, design & planning
- 9 Working problem: Welcome Module for Slicer3.4 release
- 10 Working problem: Design revision on Fiducials GUI for Slicer3.4 release
- 11 Working problem: Module Management Wizard Interface & Interaction Design Storyboard
- 12 Working problem: Consolidating Load functionality
- 13 Working problem: Save Data Widget
- 14 Working problem: Slicer & XNAT Informatics
- 14.1 Link to Fetch Medical Informatics (FetchMI) implementation 1 notes
- 14.2 Link to CTSC Use-case: Grant & Pienaar at Children's Hospital Boston
- 14.3 Link to CTSC Use-case: Brad Dickerson at Mass General NMR
- 14.4 Link to CTSC Use-case: Warfield & Weisen at Children's
- 14.5 Link to CTSC Use-case: Managing Image Guided Therapy (NCIGT) Restrospective Data at Brigham & Women's Hospital
- 14.6 Link to FetchMI XNE extension planning (work with Curtis Lisle)
- 15 Working problem: Scene Snapshot Interface
- 16 Working problem: Application-wide support for ROI definition
- 17 Working problem: Consistent checkbuttons and radiobuttons across platforms (Issue Resolved)
- 18 Working problem: Navigating with fiducials (Issue resolved: implemented in Editor module and Edit Box)
- 19 Working problem: Cine display for viewing and analyzing multi-volume data in Slicer3
- 20 Working problem: Mouse Modes in Slicer3
- 20.1 Current issues we want to address in existing Slicer3 implementation:
- 20.2 Link to Developer & user suggestions for what we need to pick
- 20.3 Link to User suggestions and Draft 1
- 20.4 Link to Notes on Selection and Direct Manipulation
- 20.5 Link to Notes on State=Selected vs. State=Active in MRML
- 20.6 Link to Other software conventions...
- 21 Background: Slicer 3.2 usability & ideas for Slicer 3.3
Slicer users
Core user communities:
- (NAC) Longitudinal and multi-channel dataset analysis
- (BIRN/NA-MIC) Individual and group analysis
- (IGT/AMIGO) Real-time control and tracking in the operating theater
- (IGT) Neurosurgical planning and guidance
Types of users:
- Algorithm researchers (who work within 3DSlicer's development environment and with associated toolkits)
- Biomedical engineers (who rely on 3DSlicer's interactive enironment and scripting capabilities)
- Application scientists (who use 3DSlicer as a desktop application and turnkey system)
User Feedback: Feature, Resource, Application Convention Requests
Please add usability feedback to Slicer3's bug tracker. If you are not familiar with the bug tracker:
- login or create an account
- choose Slicer3 as your project (upper right corner)
- and select Report Issue.
- make sure to choose the correct category for your report (select "usability" for usability issues).
Early feature requests can also be found here.
Some Embodiment History
- Earlier embodiment of main application GUI
- Earlier design for Slice Viewer and Slice Controller Widgets
- Design sketch for the 3D navigation & Slice magnifier widget
- Early look and feel draft
- First sketch of the GUI layout design
- Link to a running visual blog highlighting progress in the Slicer3 embodiment.
Codes to mark contributions
These wiki pages can be hard to parse. Here's an experiment for marking feedback to make it easier to parse; (copy, paste and customize from below).
(wjp) Add a general comment or opinion.
Report a really bad bug that's blocking work progress, or causing a crash.
Working problem: Consolidated Load in Slicer including an extended XNAT Desktop and File Server
Link to info for A. Slicer Consolidated Load and XNAT Desktop/File Server integration
Working problem: CTSC: Facilitating Tumor Analysis Workflow in Slicer
Contributors: Ron Kikinis, Jeff Yapp, Randy Gollub, Wendy Plesniak
Goals: Perform the following analyses in Slicer and create presentation & tutorial materials
- A. Single Volumetric Dataset Basic Volumetric Measurements for Tumor Assessement
- Linear
- Volumetric
- B. Dynamic Volumetric Data Visualize & Analyze Perfusion Data
- Define ROI
- Interactive Plot of Contrast Dilution as Function of Time
- Measure Peak (first priority) & Transit (second priority) times in Blood Pool & Tumor
- Save timepoints
- Intensity(t) for ROI1
- Intensity(t) for ROI2
- C. PET Dataset Basic Standardized Uptake Value (SUV) Analysis
- Segment Tumor by Hand (ROI or VOI, circle or sphere will work)
- Normalize by SUV (use maximum value)
- Extract Parameters:
- For single tumor: SUVmax_Baseline, SUVmax_Timepoint, %change
- For multi tumor: SUM(SUVmax_Baseline) - SUM(SUVmax_Timepoint), %change
- D. Visualization Requirements Displaying Static, Dynamic and PET data
- E. Presentation Materials Powerpoint Slides for CTSA IRAT
- Deadline: September (for October meeting)
- Short slideset showing Slicer overview & BC tumor analysis
- Deadline: November (for RSNA in December)
- Full slidesets including Basic Training and Specific hands-on BC tumor analysis
- Deadline: September (for October meeting)
Tutorial slides currently under development
Link to info for A. Volumetric Analysis
Link to info for B. Dynamic analysis
Link to info for C. PET Analysis
Working problem: Customizable layouts for Slicer3
Instead of a finite set of layout options, we would like to provide users the ability to select among a richer set of layouts, some created to be appropriate for analyzing certain kinds of studies, and the ability to customize their application layout as well. We have begun working on ideas at the NA-MIC January 2009 AHM.
Contributors: Jim Miller, Steve Pieper, Ron Kikinis, Wendy Plesniak
Link to first draft of user experience design
Link to first ideas about layout architecture
Working problem: Slicer3 workflow for Tractography: usability issues, design & planning
Working with Dr. Jean-Jacques Lemaire, we are understanding the use of Slicer in a complicated tractography analysis, within the context of a particular workflow. This work is identifying usability issues, software bugs, and ideas for improvement. These pages are a touchstone for the project.
Contributors: Jean-Jacques Lemaire, Nicole Aucoin, Wendy Plesniak, Steve Pieper, Alex Yarmarkovich, Andriy Fedorov, Haiying Liu
General issues, comments and feature requests
Link to Organization of Presentation Layer
Link to Naming conventions
Workflow overview and details on sub-steps
Below is a rough outline of the tractography analysis workflow currently in use (pending a proofreading check by J-J). The workflow can be broken down into general stages:
- setting up: including loading and saving and adjusting data display properties
- registration of target dataset to a reference dataset
- exploratory and analytic tractography
(if the figure should be corrected, please let me know how to fix -- maybe deformation should be part of the registration step).Data loading happens up front, but data and the scene may be saved frequently throught the workflow. Highlighted are some areas where serious usability issues have been flagged.
A plan to address these issues will be discussed on Dec 29/30 2008 at the next Slicer Developers meeting. Notes from that meeting and a proposed development plan will be posted here.
The sections below contain collected comments and suggestions for all workflow stages: Setting up, Registration, and Tractography. Markers on the figures indicate places where problems are reported.
Link to Comments on Data/Scene Loading
Link to Comments on Saving
Link to Comments on Quality check & Deformation (Pre-registration)
Link to Comments on Registration
Link to Comments on Tractography
Working problem: Welcome Module for Slicer3.4 release
Link to Mockup
Link to First Draft Implementation
Link to Second Draft Implementation
Working problem: Design revision on Fiducials GUI for Slicer3.4 release
Link to Draft1
Link to Draft2
Link to Draft3
Working problem: Module Management Wizard Interface & Interaction Design Storyboard
This wizard allows users to uninstall modules from their current build or to download and install new modules. Currently working on a usable design. Storyboard roughed out during IGT project week Dec8-12 '08, (Terry Lorber, Steve Pieper, Wendy Plesniak)
Link to Draft 1
Link to Draft 2 (not yet ready)
Working problem: Consolidating Load functionality
Functionality to load data is spread all over the application... we want to begin consolidating it in some simple fashion and to gradually implement a more integrated and appropriate solution.
Link to Draft 1
Working problem: Save Data Widget
Link to Draft 1 and notes
Link to Draft 2 and notes
Link to Draft 3 and notes
Link to Draft 4 and notes
Link to Draft 5 and notes
Working problem: Slicer & XNAT Informatics
Link to Fetch Medical Informatics (FetchMI) implementation 1 notes
Link to CTSC Use-case: Grant & Pienaar at Children's Hospital Boston
Link to CTSC Use-case: Brad Dickerson at Mass General NMR
Link to CTSC Use-case: Warfield & Weisen at Children's
Link to CTSC Use-case: Managing Image Guided Therapy (NCIGT) Restrospective Data at Brigham & Women's Hospital
Link to FetchMI XNE extension planning (work with Curtis Lisle)
Working problem: Scene Snapshot Interface
Link to Scene Snapshot UI Design
Working problem: Application-wide support for ROI definition
GOALS:
- determine relationships between label maps, implicit regions (spheres, circles, ellipses), and vector-format region definitions.
- determine what kinds of ROIs we will allow users to create/edit at application level
- determine how to expose ROI functionality application-wide (without "wormholing" to an ROI module)
- provide tools for defining, editing ROIs
- provide tools for converting ROIs into label maps (?)
- provide good mouse+hotkey design
- generalize implementation to eventually accommodate DICOM-format ROIs
- determine relationship between fiducial lists and ROIs (from implementation pov).
Link to Draft ROI design
Link to Interface & interaction design drafted at June NA-MIC Project Week
Link to Earlier notes from Editor module usability sessions
Working problem: Consistent checkbuttons and radiobuttons across platforms (Issue Resolved)
GOALS
Currently, radiobutton and checkbutton indicators display their state differently on different platforms Slicer supports. For instance, visually similar indicators on linux and windows actually represent different states. This can be confusing for people who work on both platforms. So instead of using the default Tk bitmaps for the indicators, we are proposing to use our own image data which will display the same on all platforms.
- develop a custom slicer widget as an extension of vtkKWCheckButton
- disambiguate current "deslected" radiobutton icon state -- it can be read as "disabled"
- override method for turning the old indicator visible/invisible (always keep it off)
- develop visually parseable convention for icons to represent:
- selected
- deselected
- disabled
- use methods SetImageToIcon and SetSelectImageToIcon to display selected/deselected icons, selected/deselected icons+indicators
- provide blank icons with and without indicators for people to download.
Link to Radio and check button tests
GOALS:
- use fiducials as markers for features of interest
- allow navigation to fiducial points within a slice window and
- allow navigation to same fiducial point in all slice windows (a feature we're calling 'jumpslice').
- want to read-out which fiducial is currently being viewed while navigating
- want to expose these features in top level in each slice controller widget
- want also to keep the slice scrollbar from getting too small to use.
- want to indicate which slice scrollbar direction is R,L, S,I, A,P, depending on orientation
Working problem: Cine display for viewing and analyzing multi-volume data in Slicer3
Link to Drafts of UI for Cine Display
Working problem: Mouse Modes in Slicer3
Since a left-mouse-button click in Slicer's 3D or Slice Viewers can mean different things at different times; this can be confusing to users, and can lead to mistakes. We are currently deciding a good paradigm for defining and controlling mouse modes in Slicer's 3D viewer and 2D slice windows. We rely on mouse interaction to transform the view, and to perform explicit actions like placing a fiducial, selecting and moving a fiducial, collecting voxel-value samples, and so on. The challenge is to make all actions possible with just the left mouse button (some mice have only one button), and to disambiguate what a left-mouse-button click in the 3D and Slice viewers means.
Goals: We'd like the interaction paradigm to have the following features:
- Consistent in all slice windows and 3D viewer
- Reflect common software conventions
- Intuitive and easy for beginners
- Fast for intermediate and expert users
- Rely on only one mouse button (but accommodate multiple mouse buttons)
- Support direct manipulation as much as possible
- Provide clear visual feedback about current mouse mode
- Support both view transformation (rotate, pan, zoom) as the primary mode, and mouse actions (pick, manipulate, place, etc...) as additional modes.
Current issues we want to address in existing Slicer3 implementation:
- Mouse motion should default to "transform view" mode
- Interaction relies on three mouse buttons (for rotate, pan, zoom, etc.) which aren't always present on all computers
- It's currently easy to forget about persisting non-transform mouse modes (like pick or place) and assume that the view can be transformed -- leading to annoying errors.
- Would like to free up right mouse button to invoke the display of a 'context menu', but well-established convention uses right mouse button for zooming in all viewers.
- Would like BOTH intuitive one-handed mouse-only interaction to be possible AND hot-key assisted shortcuts to be available.
- We need to combine the concepts of active (volume or model, etc.), selected (volume or model...) and picked (volume or model...)
- We need to design a consistent rendering treatment for all selected objects (model, volume, fiducial, vertex, label).
Link to Developer & user suggestions for what we need to pick
Link to User suggestions and Draft 1
Link to Notes on Selection and Direct Manipulation
Link to Notes on State=Selected vs. State=Active in MRML
Link to Other software conventions...
Background: Slicer 3.2 usability & ideas for Slicer 3.3