Difference between revisions of "Modules:OrientImages-Documentation-3.6"

From Slicer Wiki
Jump to: navigation, search
Line 43: Line 43:
  
 
* '''Input/output panel:'''
 
* '''Input/output panel:'''
 +
[[Image:OrientImage-IOPanels-3-6.png|thumb|right|280px|Input/Output panels]]
 +
User specifies the input volume and creates an output volume.
  
 
* '''Parameters panel:'''
 
* '''Parameters panel:'''
 +
[[Image:OrientImage-OrientationPanels-3-6.png|thumb|right|280px|Orientation panels]]
 +
User selects the desired orientation.
  
 
* '''Viewing panel:'''
 
* '''Viewing panel:'''

Revision as of 01:28, 27 April 2010

Home < Modules:OrientImages-Documentation-3.6

Return to Slicer 3.6 Documentation

Gallery of New Features

Module Name

Orient Images

Orient Images UI

General Information

Module Type & Category

Type: CLI

Category: Converters

Authors, Collaborators & Contact

  • Author: Bill Lorensen
  • Contact: bill.lorensen at gmail.com

Module Description

Orients an output volume. Rearranges the slices in a volume according to the selected orientation. The slices are not interpolated. They are just reordered and/or permuted. The resulting volume will cover the original volume. NOTE: since Slicer3 takes into account the orientation of a volume, the re-oriented volume will not show any difference from the original volume, To see the difference, save the volume and display it with a system that either ignores the orientation of the image (e.g. Paraview) or displays individual images.

Usage

Examples, Use Cases & Tutorials

  • This module is useful for transforming volume from its original orientation to a given orientation. Note, that the module does not align the voxel space axes with the physical space axes. If your input image is not axis-aligned, the output will preserve the direction cosines of the input image. It does not change the spatial position and orientation of the volume in the physical space.

When combined with "Create a Dicom Series" module, one can synthesize a sagittal acquisition from an axially acquired volume.

  • A command line example of the module is
 OrientImage
   --orientation Axial 
   ${MRML_DATA}/fixed.nrrd 
   ${TEMP}/OrientImageTestAxial.nrrd

Quick Tour of Features and Use

List all the panels in your interface, their features, what they mean, and how to use them. For instance:

  • Input/output panel:
Input/Output panels

User specifies the input volume and creates an output volume.

  • Parameters panel:
Orientation panels

User selects the desired orientation.

  • Viewing panel:

Note, that the module does not align the voxel space axes with the physical space axes. If your input image is not axis-aligned, the output will preserve the direction cosines of the input image.

Development

Dependencies

Other modules or packages that are required for this module's use.

Known bugs

Follow this link to the Slicer3 bug tracker.

Usability issues

Follow this link to the Slicer3 bug tracker. Please select the usability issue category when browsing or contributing.

Source code & documentation

Source Code: OrientImage.cxx

XML Description: Orient orientImage.xml

Usage:

./OrientImage  [--processinformationaddress <std::string>] [--xml]
               [--echo] [-o <Axial|Coronal|Sagittal|RIP|LIP|RSP|LSP|RIA
               |LIA|RSA|LSA|IRP|ILP|SRP|SLP|IRA|ILA|SRA|SLA|RPI|LPI|RAI
               |LAI|RPS|LPS|RAS|LAS|PRI|PLI|ARI|ALI|PRS|PLS|ARS|ALS|IPR
               |SPR|IAR|SAR|IPL|SPL|IAL|SAL|PIR|PSR|AIR|ASR|PIL|PSL|AIL
               |ASL>] [--] [--version] [-h] <std::string> <std::string>


Where: 

--processinformationaddress <std::string>
  Address of a structure to store process information (progress, abort,
  etc.). (default: 0)

--xml
  Produce xml description of command line arguments (default: 0)

--echo
  Echo the command line arguments (default: 0)

-o <Axial|Coronal|Sagittal|RIP|LIP|RSP|LSP|RIA|LIA|RSA|LSA|IRP|ILP|SRP
   |SLP|IRA|ILA|SRA|SLA|RPI|LPI|RAI|LAI|RPS|LPS|RAS|LAS|PRI|PLI|ARI|ALI
   |PRS|PLS|ARS|ALS|IPR|SPR|IAR|SAR|IPL|SPL|IAL|SAL|PIR|PSR|AIR|ASR|PIL
   |PSL|AIL|ASL>,  --orientation <Axial|Coronal|Sagittal|RIP|LIP|RSP|LSP
   |RIA|LIA|RSA|LSA|IRP|ILP|SRP|SLP|IRA|ILA|SRA|SLA|RPI|LPI|RAI|LAI|RPS
   |LPS|RAS|LAS|PRI|PLI|ARI|ALI|PRS|PLS|ARS|ALS|IPR|SPR|IAR|SAR|IPL|SPL
   |IAL|SAL|PIR|PSR|AIR|ASR|PIL|PSL|AIL|ASL>
  Orientation choices (default: LPS)

--,  --ignore_rest
  Ignores the rest of the labeled arguments following this flag.

--version
  Displays version information and exits.

-h,  --help
  Displays usage information and exits.

<std::string>
  (required)  Input volume 1

<std::string>
  (required)  The oriented volume


Description: Orients an output volume. Rearranges the slices in a volume
accoording to the selected orientation. The resulting volume will cover
the original volume.

Author(s): Bill Lorensen

Acknowledgements: This work is part of the National Alliance for Medical
Image Computing (NAMIC), funded by the National Institutes of Health
through the NIH Roadmap for Medical Research, Grant U54 EB005149.

More Information

Acknowledgment

This work is part of the National Alliance for Medical Image Computing (NAMIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Information on the National Centers for Biomedical Computing can be obtained from National Centers for Biomedical Computing.

References