Difference between revisions of "Documentation/Nightly/Modules/DicomRtImport"

From Slicer Wiki
Jump to: navigation, search
Line 56: Line 56:
 
Custom attributes:
 
Custom attributes:
 
* DicomRtImport.DoseUnitName: set in each imported dose volume, the value of this attribute is read from the Dose Units (3004,0002) attribute of the RTDOSE DICOM volume
 
* DicomRtImport.DoseUnitName: set in each imported dose volume, the value of this attribute is read from the Dose Units (3004,0002) attribute of the RTDOSE DICOM volume
* DicomRtImport.DoseUnitValue: set in each imported dose volume, the value of this attribute is read from the Dose Grid Scaling (3004,000E) attribute of the RTDOSE DICOM volume. This value defines a scaling factor to convert the integer voxel values of the dose volume in the DICOM file to real dose values. This conversion is performed during DICOM importing, but this value is stored to let other modules know what was the original scaling factor (e.g., see how it is used in the documentation of the Dose Volume Histogram module)
+
* DicomRtImport.DoseUnitValue: set in each imported dose volume, the value of this attribute is read from the Dose Grid Scaling (3004,000E) attribute of the RTDOSE DICOM volume. This value defines a scaling factor to convert the integer voxel values of the dose volume in the DICOM file to real dose values. This conversion is performed during DICOM importing, but this value is stored to let other modules know what was the original scaling factor (e.g., see how it is used in the documentation of the [[Documentation/{{documentation/version}}/Modules/DoseVolumeHistogram|Dose Volume Histogram]] module)
  
 
{{documentation/{{documentation/version}}/module-developerinfo}}
 
{{documentation/{{documentation/version}}/module-developerinfo}}

Revision as of 13:55, 21 February 2013

Home < Documentation < Nightly < Modules < DicomRtImport

Introduction and Acknowledgements

This work is part of the SparKit project, funded by An Applied Cancer Research Unit of Cancer Care Ontario with funds provided by the Ministry of Health and Long-Term Care and the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions.
Authors: Andras Lasso (PerkLab, Queen's University), Steve Pieper (Isomics), Kevin Wang (Radiation Medicine Program, Princess Margaret Hospital, University Health Network Toronto), Csaba Pinter (PerkLab, Queen's University)
Contact: Andras Lasso, <email>lasso@cs.queensu.ca</email>

Cancer Care Ontario  
Software Platform and Adaptive Radiotherapy Kit  

Module Description

The DicomRtImport module enables importing and loading DICOM RT files into the Slicer DICOM database and the Slicer scene.

DicomRtImport does not have a separate module GUI. Instead, it is a DICOM import plugin that extends the DICOM module.

When the user selects a patient in the DICOM management module interface, the import mechanism allows each DICOM import module to interpret the data. The DICOM import modules parse the data and return a list of items that they can read from the selected DICOM objects. This module will return with the RT objects. The DICOM module displays the consolidated list of all loadable objects to the user, and loads the items that are selected by the user.

Use Cases

Import and load DICOM RT data

Dose volume histogram computation using SlicerRT

Tutorials

N/A

Panels and their use

See module description

Similar Modules

N/A

References

N/A

Information for Developers

Custom attributes:

  • DicomRtImport.DoseUnitName: set in each imported dose volume, the value of this attribute is read from the Dose Units (3004,0002) attribute of the RTDOSE DICOM volume
  • DicomRtImport.DoseUnitValue: set in each imported dose volume, the value of this attribute is read from the Dose Grid Scaling (3004,000E) attribute of the RTDOSE DICOM volume. This value defines a scaling factor to convert the integer voxel values of the dose volume in the DICOM file to real dose values. This conversion is performed during DICOM importing, but this value is stored to let other modules know what was the original scaling factor (e.g., see how it is used in the documentation of the Dose Volume Histogram module)