Difference between revisions of "Documentation/4.0/Modules/N4ITKBiasFieldCorrection"
From Slicer Wiki
(Created page with '<!-- ---------------------------- --> {{documentation/{{documentation/version}}/module-header}} <!-- ---------------------------- --> <!-- ---------------------------- --> {{doc…') |
|||
| Line 17: | Line 17: | ||
{{documentation/{{documentation/version}}/module-section|Module Description}} | {{documentation/{{documentation/version}}/module-section|Module Description}} | ||
| + | {{documentation/{{documentation/version}}/module-cli-description|xmlurl={{documentation/{{documentation/version}}/module-cli-xmlurl|{{documentation/modulename}}|17817}} }} | ||
| + | <!-- ---------------------------- --> | ||
| + | {{documentation/{{documentation/version}}/module-section|Use Cases}} | ||
| + | |||
| + | This module is especially appropriate for these use cases: | ||
| + | * Image acquisition is done with a surface coil, and you observe signal fall-off as you get further away from the coil (this is particularly the case at higher field strengths) | ||
| + | * You observe smooth variation of the intensity over the tissue that should have intensity close to uniform | ||
| + | * Your attempts to segment or register your data are not successful, and you are not sure what to do next | ||
| + | |||
| + | Examples of the module in use: | ||
| + | |||
| + | * Correction of the signal inhomogeneity in prostate MRI obtained with endorectal coil at 3T field strength | ||
{| | {| | ||
|[[Image:n4_prostate_input_ax.png|thumb|280px|Prostate erMRI]] | |[[Image:n4_prostate_input_ax.png|thumb|280px|Prostate erMRI]] | ||
| Line 24: | Line 36: | ||
|} | |} | ||
| − | + | * Correction of the bias in vervet MRI. Acquisition parameters: 3T GE scanner, single-channel dedicated RF coil (Litzcage, Doty Scientific, Columbia, SC); 3D SPGR sequence (TI 600ms, TE 3.276ms, TR 15.28ms; flip angle 15 deg; matrix 256x256; FOV 12cm; in-plane resolution 0.47 mm; slice thickness 0.5 mm). | |
| − | + | {| | |
| − | + | |[[Image:n4_mark1_input.png|thumb|280px|Slice of the input test volume with apparent bias field and label outlines]] | |
| − | + | |[[Image:n4_mark1_output.png|thumb|280px|Output image visually contains less inhomogeneity]] | |
| − | + | |[[Image:n4_mark1_subtract.png|thumb|280px|Before - After subtract image]] | |
| − | + | |[[Image:n4_mark1_bias.png|thumb|280px|Recovered bias field]] | |
| − | + | |} | |
| + | |||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
Revision as of 13:58, 20 October 2011
Home < Documentation < 4.0 < Modules < N4ITKBiasFieldCorrection
Introduction and Acknowledgements
- This work is part of the National Alliance for Medical Image Computing (NA-MIC), funded by the National Institutes of Health through the NIH Roadmap for Medical Research, Grant U54 EB005149. Information on NA-MIC can be obtained from the NA-MIC website. The development of this module was supported in part by NIH grants R01 AA016748-01, R01 CA111288 .... check grants.
- Authors: Nick Tustison (N4ITK filters), Ron Kikinis (PI + design and inspiration), Andrey Fedorov (design, ITK filter modifications, 3D Slicer module)
- Contact: Andrey Fedorov, <email>fedorov@bwh.harvard.edu</email>
Module Description
Template:Documentation/4.0/module-cli-description
Use Cases
This module is especially appropriate for these use cases:
- Image acquisition is done with a surface coil, and you observe signal fall-off as you get further away from the coil (this is particularly the case at higher field strengths)
- You observe smooth variation of the intensity over the tissue that should have intensity close to uniform
- Your attempts to segment or register your data are not successful, and you are not sure what to do next
Examples of the module in use:
- Correction of the signal inhomogeneity in prostate MRI obtained with endorectal coil at 3T field strength
- Correction of the bias in vervet MRI. Acquisition parameters: 3T GE scanner, single-channel dedicated RF coil (Litzcage, Doty Scientific, Columbia, SC); 3D SPGR sequence (TI 600ms, TE 3.276ms, TR 15.28ms; flip angle 15 deg; matrix 256x256; FOV 12cm; in-plane resolution 0.47 mm; slice thickness 0.5 mm).
Tutorials
Links to tutorials that use this module
Panels
Template:Documentation/4.0/module-cli-parametersdescription
Panels
- Point to other modules that have similar functionality
References
Publications related to this module go here. Links to pdfs would be useful. For extensions: link to the source code repository and additional documentation
Information for Developers
| Section under construction. |