Difference between revisions of "Documentation/4.3/Modules/DoseComparison"
m (Text replacement - "slicerWiki/index.php" to "wiki") |
|||
Line 12: | Line 12: | ||
Contributor: Greg Sharp (Massachusetts General Hospital)<br> | Contributor: Greg Sharp (Massachusetts General Hospital)<br> | ||
Contact: Csaba Pinter, <email>pinter@cs.queensu.ca</email><br> | Contact: Csaba Pinter, <email>pinter@cs.queensu.ca</email><br> | ||
− | [http://www.slicer.org/ | + | [http://www.slicer.org/wiki/Documentation/Nightly/Extensions/SlicerRT Back to SlicerRT home] |
{{documentation/{{documentation/version}}/module-introduction-row}} | {{documentation/{{documentation/version}}/module-introduction-row}} | ||
{{documentation/{{documentation/version}}/module-introduction-logo-gallery | {{documentation/{{documentation/version}}/module-introduction-logo-gallery | ||
Line 36: | Line 36: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Tutorials}} | {{documentation/{{documentation/version}}/module-section|Tutorials}} | ||
− | See [http://www.slicer.org/ | + | See [http://www.slicer.org/wiki/Documentation/Nightly/Extensions/SlicerRT#Tutorials SlicerRT main page] |
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
Line 49: | Line 49: | ||
<!-- ---------------------------- --> | <!-- ---------------------------- --> | ||
{{documentation/{{documentation/version}}/module-section|Similar Modules}} | {{documentation/{{documentation/version}}/module-section|Similar Modules}} | ||
− | [http://www.slicer.org/ | + | [http://www.slicer.org/wiki/Documentation/Nightly/Modules/ContourComparison Contour Comparison] |
<!-- ---------------------------- --> | <!-- ---------------------------- --> |
Latest revision as of 17:33, 21 November 2019
Home < Documentation < 4.3 < Modules < DoseComparison
For the latest Slicer documentation, visit the read-the-docs. |
Introduction and Acknowledgements
This work is part of the SparKit project, funded by An Applied Cancer Research Unit of Cancer Care Ontario with funds provided by the Ministry of Health and Long-Term Care and the Ontario Consortium for Adaptive Interventions in Radiation Oncology (OCAIRO) to provide free, open-source toolset for radiotherapy and related image-guided interventions. | |||||||
|
Module Description
The DoseComparison module computes the difference between two co-registered dose volumes using the gamma dose distribution comparison method. This module uses the gamma Plastimatch algorithm internally.
Use Cases
Comparing dose distributions
Tutorials
Panels and their use
- Current contour(s): Currently selected contour node (vtkMRMLContourNode) or conotur hierarchy node (vtkMRMLContourHierarchyNode)
- Active representation: The active representation (Ribbon model / Indexed labelmap / Closed surface model) of the selected contour. If a hierarchy is selected in which the active representations of the contained contours do not match, Various is indicated
- Change active representation: This box contains controls to convert from one representation to another
Similar Modules
References
- Low, D. A.; Harms, W. B.; Mutic, S. & Purdy, J. A. A technique for the quantitative evaluation of dose distributions Med. Phys, 1998, 25 (5), 656/6
- Low, D. A. & Dempsey, J. F. Evaluation of the gamma dose distribution comparison method Med. Phys, 2003, 30 (9), 2455/10
Information for Developers
N/A