Line 54: | Line 54: | ||
* Do the same for the Output Volume menu | * Do the same for the Output Volume menu | ||
* Modify the parameter values if desired (default values gave good results during our experiments) | * Modify the parameter values if desired (default values gave good results during our experiments) | ||
− | * Click on Apply | + | * Click on Apply. |
It took 32 min to process a 512x512x30 MRI volume on a MacBook laptop. | It took 32 min to process a 512x512x30 MRI volume on a MacBook laptop. | ||
+ | To visualize the result: | ||
+ | * Deselect the Overlay volume, | ||
+ | * Select the input as Background volume and the output as Foreground volume. | ||
+ | * Go to Modules > Volumes | ||
+ | * Select the input volume, and write down the values for Window and Level | ||
+ | * Select the output volume, and apply the same values | ||
+ | * Move the lower left cursor in 'Manipulate Slice Views' between B (background) and F (foreground) | ||
===Examples, Use Cases & Tutorials=== | ===Examples, Use Cases & Tutorials=== |
Revision as of 00:16, 18 August 2009
Home < Modules:MRIBiasFieldCorrection-Documentation-3.5Return to Slicer 3.5 Documentation
MRI Bias Field Correction
Filtering:MRIBiasFieldCorrection
This module enables the user to get a fast preview of the Bias Field Correction applied on a 2D slice. The advantage of this preview is to try different parameters and visualize the effect in real time.
A Command Line version of this module has been developed to enable the Slicer3 Testing framework. Hence this module is tested during every Nightly build and the result is reported in the Slicer3 Dashboard.
General Information
Module Type & Category
Type: Interactive or CLI
Category: Filtering
Authors, Collaborators & Contact
- Nicolas Rannou: Harvard Medical School, Brigham and Women's Hospital
- Sylvain Jaume: MIT Computer Science and Artificial Intelligence Laboratory
- Contact: <nrannou at bwh.harvard.edu>, <sylvain at csail.mit.edu>
Module Description
The module filters the image to remove the intensity inhomogeneity due to the MRI image acquisition.
Usage
- Load the input dataset (Main menu: Add Volume)
- Create a Mask Volume using the Editor (Modules > Editor) (the Threshold tool should give a good result)
- Select the MRIBiasFieldCorrection module (Modules > Filtering > MRIBiasFieldCorrection)
- In the left panel, select the Input Volume
- Select the Mask Volume
- In the Preview Volume menu , select 'Create New Volume'
- Do the same for the Output Volume menu
- Modify the parameter values if desired (default values gave good results during our experiments)
- Click on Apply.
It took 32 min to process a 512x512x30 MRI volume on a MacBook laptop. To visualize the result:
- Deselect the Overlay volume,
- Select the input as Background volume and the output as Foreground volume.
- Go to Modules > Volumes
- Select the input volume, and write down the values for Window and Level
- Select the output volume, and apply the same values
- Move the lower left cursor in 'Manipulate Slice Views' between B (background) and F (foreground)
Examples, Use Cases & Tutorials
- Note use cases for which this module is especially appropriate, and/or link to examples. (to be defined)
- Link to examples of the module's use (to be defined)
- Link to any existing tutorials (to be defined)
Quick Tour of Features and Use
List all the panels in your interface, their features, what they mean, and how to use them. For instance:
- Input panel:
- Parameters panel:
- Output panel:
- Viewing panel:
Development
Dependencies
No other modules or packages are required to use this module.
Known bugs
Follow this link to the Slicer3 bug tracker.
Usability issues
Follow this link to the Slicer3 bug tracker. Please select the usability issue category when browsing or contributing.
Source code & documentation
More Information
Acknowledgment
This work has been supported by NA-MIC Algorithms.